Review a revision
Select the previous and revised STEP once. Inspect health, structure, sampled surface distances, Boolean volumes and PMI values in one session.
For single-solid inputs, automatic targets 16 area samples per face up to a 20,000-sample budget. Large models use at least 4 per face within the 5,000-face limit; density is recorded per face. Higher counts are not certified accuracy. This choice applies to new distance stages; retained measurements keep their recorded budget.
A saved five-stage session can add this stage through Continue missing stages. Already recorded Boolean evidence is retained when continuing, regardless of this selection.
Existing session stages are retained. PMI attributes are observations, not semantic GD&T validation. Older application packages cannot open sessions extended with PMI.
Multi-solid automatic sampling: 1,000 area samples per body and direction, raised to at least four per face. Body sessions start a fresh run when recalculated; per-body budgets and unresolved pairs are recorded.
To refine a saved revision, select the same two STEP files and a new area-sampling budget, then recalculate surface distances only. Other completed stages are retained. If the new distance run fails or is cancelled, the previous session stays available. Save the new session to keep it.
Experimental workflow · verification pending. Multi-solid inputs are paired by unique name paths; ambiguous bodies remain unmatched.
Results available during this run
This is a partial snapshot. Unfinished stages are marked incomplete. The previously opened result below remains unchanged until the run finishes. When continuing a saved session, its review notes are preserved. Notes whose evidence has changed require revalidation; saving does not approve them.
Recorded detail
The revision and its notes remain unchanged. Close this panel to return to the summary.
Observed findings
Where is the difference?
Baseline OCCT tessellation provides visual context only; measurements do not use the mesh. Colored points are measured samples. Drag or use arrow keys to rotate. Select a region to focus. Gaps are unmeasured.
Unresolved scope
Same ordered STEP bytes required. Opens recorded observations without recalculating. This comparison is separate from the current session report.
Save both session JSON files to reopen this comparison later. The current session JSON contains only its own measurements.
Record an engineering review note
Annotations are separate from measurement findings. Save the session JSON after adding notes. If the referenced evidence changes when continuing, its notes need revalidation.
Names and timestamps are self-declared, not authenticated signatures. Up to 200 notes. A session with notes uses a review wrapper that older releases, including R4, do not open.
Stage evidence and detailed tools
Scope and interpretation
Health, candidate structure pairing and the selected area-sampling budget per direction, when eligible. Imported coordinates; no automatic alignment. Positive distances and placement differences are recorded observations. No observed difference does not prove unchanged geometry. This workflow does not decide conformity or reprogramming. Boolean volumes are included when selected and both health prerequisites hold; zero or equal volumes do not establish equivalence. Semantic PMI is outside this session.
Completed stage records stay available after later failures or cancellation. Continue missing stages requires the same two STEP byte snapshots in the same order; it preserves existing completed evidence without recalculation. Select Start new revision summary to rerun all stages. Retained and new stages may have different runtimes; each retains its evidence. Open recorded detail transfers a completed health, structure or distance record to its tool without recalculation. Keep the revision tab open until it is received. JSON download remains available for every completed stage. All processing stays on this computer. Session and component records may contain confidential source names.